Bierer Service Tester
Bierer Service Tester
*Usually ships within 7 to 14 days.
- Puts high magnitude pulse between the neutral/ hot leg or hot leg / hot leg for any secondary service (120V,208,277,480V)
- It cannot be fooled by telephone and cable television bonding often missed by continuous loading devices
- Identify bad conductos(s) from the transfomer to the meter baseÂ
- Indicate integrity of neutral conductor to prevent excessive house ground currents
- Locate both hot legs and neutral at the pedestal and / or transformer blocks
- Locate bad connectors on overhead spans
- Identify de- energized URD Primary cable in a manhole or ditch
- Laser Pyrometer not shown